PBXX-30/24AC (series) PBX-30/24AC
|
Ibex Manufacturing, Inc. |
|
Operating Ratings | |
|
AC Line Voltage (note 1) DC Line Voltage (note 2) DC Line Current (note 3) Isolation from Ground (note 4) Output Short Circuit Duration AC Line Frequency (Min. & Max.) Operating Temperature Storage Temperature MTBF (Calculated) |
21.6VRMS - 26.4VRMS 9VDC - 36VDC 3.0A 150V peak Continuous 50Hz - 400Hz -40C to +85C -55C to +105C 150,000 Hours (25C) |
| Parameter | Conditions | Minimum | Maximum | Units |
| Max. Output Current (Note 5) | Each output | 3.0 | 3.5 | A |
| Min. Load Current (Note 6) | Each output | 15 | - | mA |
| Output Ripple & Noise (Note 7) | Before extra filtering | - | 100 | mV pk-pk |
| Output Ripple & Noise | After extra filtering | - | 20 | mV pk-pk |
|
Note 1: The supply is designed to be powered by a 24VAC, 56VA transformer for 30W output power at
Note 2: The DC voltage
Note 3: The average DC input current (if used) should not be allowed to greatly exceed
Note 4: This assumes the board is mounted on metal standoffs with #6 screws. If 3/8" nylon standoffs and #6 nylon screws are used, the isolation is 4,000V peak or the isolation rating of the transformer or DC
Note 5: The regulator circuit automatically limits the output current to Note 6: A minimum load current of 15mA is required to maintain regulation.
Note 7: There is an extra-filtered output available for each voltage. The resistance of the filter is approximately 0.05 ohms which gives the choice between lower ripple and tighter regulation. |
|
[ General ] [ Operation ] [ Mechanical ] |
|
|
| low temperature 14v power supply supplies, high temperature 14v power supply supplies, low temp 14v power supply supplies, high temp 14v power supply supplies, wide temperature 14v power supply supplies, wide temp 14v power supply supplies, extreme temperature 14v power supply supplies, extreme temp 14v power supply supplies, extreme environment 14v power supply supplies |